FFULL=0, ACDSEL=0, ADTRG=0, ACFE=0, ADACT=0, FEMPTY=0
Status and Control Register 2
RESERVED | no description available |
FFULL | Result FIFO full 0 (0): Indicates that ADC result fifo is not full and next conversion data still can be stored into fifo. 1 (1): Indicates that ADC result fifo is full and next conversion will override old data if no read action. |
FEMPTY | Result FIFO empty 0 (0): Indicates that ADC result fifo have at least one valid new data. 1 (1): Indicates that ADC result fifo have no valid new data. |
ACDSEL | Compare Data Selection 0 (0): Compare value is from the conversion result and ADC_CVA. 1 (1): Compare value is from the conversion result and ADC_CVB. |
ACFE | Compare Function Enable 0 (0): Compare function disabled. 1 (1): Compare function enabled. |
ADTRG | Conversion Trigger Select 0 (0): Software trigger selected. 1 (1): Hardware trigger selected. |
ADACT | Conversion Active 0 (0): Conversion not in progress. 1 (1): Conversion in progress. |
RESERVED | no description available |